Fire / Smoke Door
5
Category
Reading
Confirmation
Add Photo
Risk Assessment
Add Notes
Operation
6
The door swings freely without obstruction
Open
The door closes properly
Open
The door latches reliably
Open
Coordinator works properly
Yes
Open
The electric holder releases properly
Yes
Open
The door swings freely, without rubbing against the floor, frame or another door
Open
Frame
11
The frame is securely anchored to the wall
Open
The frame is sealed, without any open holes or unused fastener holes
Open
There is no rust on the door frame
Open
The door frame is properly aligned
Open
The label is present on the door frame
Open
The label is legible on the door frame
Open
The door frame has zero non-compliant field modifications
Open
The door frame has no incorrect/broken/missing glass
Open
The door frame has no broken or missing glazing beads
Open
The door frame’s glazing bead is fastened correctly
Open
The door frame has compliant glass light configuration
Open
Door
13
The door has correct clearance
Open
The door has no open holes or unused fastener holes
Open
The door is not damaged or delaminated
Open
There is no rust on the door
Open
The door label is not missing
Open
The door label is legible
Open
The door is free of non compliant field modifications
Open
The door is free of incorrect/broken/missing glass
Open
The door is free of broken/missing glazing bead
Open
The glazing bead is correctly fastened to the door
Open
The door has compliant glass light configuration
Open
The door has compliant plant-ons
Open
The door is properly installed
Open
Hinges/Pivot
4
The door hinges/pivots are the correct types
Open
There are no missing hinges/pivots on the door
Open
The door hinges/pivots have the correct fasteners
Open
The door hinges/pivots are securely fastened
Open
Flush Bolts/Coordinator
7
The door has the correct flush bolts/coordinator
Open
The door does not have missing or damaged bolts
Open
The door does not have missing or damaged strikes
Open
The door’s coordinator is functioning properly
Yes
Open
The door’s bolt does not engage strike
Open
The door has proper fasteners
Open
The door’s flush bolts and coordinator are securely fastened
Open
Locket/Latch set
7
The door’s locket/latchet is not missing or damaged
Open
The locket/latchset strike is not missing or damaged
Open
The latch throw is compliant
Open
The latch is listed
Open
The latch does not engage strike
Open
The locket/latchset has the proper fasteners
Open
The locket/latchset is securely fastened
Open
Fire Exit Hardware
9
The door has a missing or damaged exit device
Yes
Open
The door’s fire exit device has a missing or damaged strike
Open
The door’s fire exit device has a missing or damaged latch
Open
The door’s fire exit device is a listed device
Open
The fire exit device’s actuating portion is not less than half of the door width
Open
The fire exit device’s latch does not engage the strike
Open
The fire exit device does not have missing or incorrect fasteners
Open
The fire exit device is securely fastened
Open
The fire exit device has complant mullion
Open
Door Closure
6
The door closure is not missing or damaged
Open
The door closer does not have a missing or damaged arm
Open
The door closer does not have missing or incorret fasteners
Open
The door closer is securely fastened
Open
The door closure is not leaking
Open
The door closer has a hold open arm
Yes
Open
Other
3
The door has no damaged, missing or incorrect seals
Open
The door has a compliant protection plate
Open
The door has a compliant signage
Yes